1
100
1
-
https://richesmi.cah.ucf.edu/omeka/files/original/e252cbb618ebc8b49838e33e2edf937e.pdf
8bdb766fe7259b95280e95c1490d80d4
Dublin Core
The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.
Title
Westinghouse Electric Collection
Alternative Title
Westinghouse Collection
Subject
Westinghouse Electric Corporation
Description
Originally called the Westinghouse Electric Company, George Westinghouse (1846-1914) founded his manufacturing company in Pittsburgh, Pennsylvania, on January 8, 1886. In 1889, he renamed his business the The Westinghouse Electric and Manufacturing Company. Westinghouse's primary products include turbines, generators, motors and switchgear related to the generation, transmission, and use of electricity. The company changed its name to Westinghouse Electric Corporation in 1945. In 1981, the company began to relocate its divison headquarters for the Steam-Turbine Generator Divisions from Pennsylvania (turbines from Lester and generators from Pittsburgh) to Orlando, Florida. The Power Generation Business Unit (PGBU) building was located in The Quadrangle, at 4400 Alafaya Trail. Originally, Westinghouse had purchased a large plot of land for future development that extended westward from Alafaya Trail to Rouse Road. The original headquarters was located on several acres of that land parcel close to Alafaya Trail.<br /><br />In 1994, after a major corporate management shuffling, and a top-level decision to change from an industrial manufacturing company to primarily a broadcasting/communications company, Westinghouse bought the CBS Network and changed its name to the CBS Corporation. As the PGBU grew in size, other buildings in the area were leased and then, after PGBU was sold to Siemens Corporation of Germany in 1998, additional buildings (Quad II and Quad III) were added to the original complex at the Quadrangle. From 1998 to 2003 the Orlando operation was known as Siemens-Westinghouse, after which the name of Westinghouse was dropped. The operation has been known as Siemens from that time forward.
Is Part Of
<a href="https://richesmi.cah.ucf.edu/omeka2/" target="_blank">RICHES of Central Florida</a>.
Language
eng
Type
Collection
Coverage
Orlando, Florida
Curator
DeRosa, Peter
Cepero, Laura
Digital Collection
<a href="https://richesmi.cah.ucf.edu/map/" target="_blank">RICHES MI</a>
External Reference
"<a href="http://www.westinghousenuclear.com/About/History" target="_blank">History</a>." Westinghouse Nuclear. http://www.westinghousenuclear.com/About/History.
"<a href="https://richesmi.cah.ucf.edu/omeka2/items/show/6422" target="_blank">Westinghouse Power Generation Booklet</a>." RICHES of Central Florida. https://richesmi.cah.ucf.edu/omeka2/items/show/6422.
Document
A resource containing textual data. Note that facsimiles or images of texts are still of the genre text.
Original Format
23-page brochure
Dublin Core
The Dublin Core metadata element set is common to all Omeka records, including items, files, and collections. For more information see, http://dublincore.org/documents/dces/.
Title
Combustion Turbine Cogeneration
Alternative Title
Combustion Turbine Cogeneration
Subject
Westinghouse Electric Corporation
Turbines
Description
This item is a brochure produced by Westinghouse Combustion Turbine Systems Division in Concordville, Pennsylvania, to describe the application of the 50MW model W251B10 and 100MW W501D5 combustion turbines (a.k.a. gas turbines) for use in cogeneration plants. Such plants were built for the simultaneous production of both electric energy and useful thermal energy for industrial process use. In the early 1980s, cogeneration became very popular among independent (non-utility) power generators (or Independent Power Producers, IPPs) since it enabled the owner to obtain an exemption from the Fuel Use Act, which, as part of the broad National Energy Act of 1978, specifically prohibited the base load (i.e. continuous year-'round) production of electricity using oil or natural gas fuels. Cogeneration plants were exempt from the Fuel Use Act due to their high efficiency compared to power-only generating plants. Also, owners of cogeneration plants were allowed to sell the electricity that they produced to the local electric utility company under another part of the National Energy Act, namely, the Public Utility Regulatory Policies Act, popularly known as "PURPA." the brochure provides data on the power and efficiency (heat rate) of the W251B10 and W501D5 gas turbines, as well data on the steam production capability by each via use of heat recovery boilers or steam generators.
Type
Text
Source
Original 23-page brochure: Private Collection of Harry Jaeger.
Requires
<a href="http://www.adobe.com/products/reader.html" target="_blank">Adobe Acrobat Reader</a>
Is Part Of
<a href="https://richesmi.cah.ucf.edu/omeka2/collections/show/169" target="_blank">Westinghouse Electric Collection</a>, RICHES of Central Florida.
Is Format Of
Digital reproduction of original 23-page brochure.
Coverage
Combustion Turbine Systems Division, Westinghouse Electric Corporation, Concordville, Pennsylvania
Turbine and Generator Division, Westinghouse Canada, Inc., Hamilton, Ontario, Canada
Publisher
Westinghouse Electric Corporation
Contributor
Jaeger, Harry
Date Created
1983
Date Copyrighted
1983
Format
application/pdf
Extent
2.91 MB
Medium
23-page brochure
Language
eng
Mediator
History Teacher
Science Teacher
Provenance
Originally published by Westinghouse Electric Corporation.
Rights Holder
Copyright to this resource is held by Westinghouse Electric Corporation and is provided here by <a href="http://riches.cah.ucf.edu/" target="_blank">RICHES of Central Florida</a> for educational purposes only.
Accrual Method
Donation
Curator
Jaeger, Harry
Cepero, Laura
Digital Collection
<a href="https://richesmi.cah.ucf.edu/map/" target="_blank">RICHES MI</a>
Source Repository
Westinghouse Electric Corporation Archives
External Reference
Nordhaus, R. 1995. "<a href="http://www.worldcat.org/oclc/4434334178" target="_blank">The National Energy Act of 1978</a>." Natural Resources and Environment. 10, no. 1: 62-68.
AFB
atmospheric fluid bed
Availability Assurance Engineering
Benjamin Franklin
bubbling bed system
circulating bed system
cogeneration
Combustion Turbine Systems Division
combustion turbines
combustors
compressors
Configuration Visibility system
electrical energy
electricity
energy
engines
gasification
George Westinghouse, Jr.
heat recovery steam generators
HRSG
industrial electrification
Mississippi River Fuel Corporation
power plants
Special Westinghouse Assistance Team
SWAT
thermal energy
Turbine Generator System
W21
W251B
W501
W501D
Westinghouse Canada, Inc.
Westinghouse Electric Corporation